1. Pressurized system

A kit of brass inlet / outlet fittings is used to connect the inter-panel links to the transfer circuit.

  • M3/4’’ for DN15 inter-panel links
  • M1’’ for DN26 inter-panel links

This kit includes, for a line of panels:

  • 4 corrugated fittings
  • 4 hose clamps
  • 4 high temperature fiber O-rings
  • 2 screw caps
kit_de_raccords_entr_e_sortie_ECS.png

 

These fittings are installed at the inlet and outlet of each line of sensors.

 

Assembly of the clamp:

  • Place the clamp on the hose (1)
  • Insert the barbed fitting into the hose (2)
  • Tighten up to the stop (3) - <!> Do not squeeze any tighter
    installation_kit_de_raccords_entr_e_sortie_ECS.png

Assembly of the screw cap:

  • Place the screw cap with the fiber gasket supplied in the inlet / outlet fitting kit
  • Screw on the cap so that the fiber gasket is firmly in place
  • Tightening of screw caps = 40 Nm maximum            

Note: It is advisable to moisten the fiber gasket supplied in the inlet/outlet connection kit before installation, however a dry gasket installation is acceptable.

 

bouchon_kit_de_raccords_entr_e_sortie_ECS.png

 

The inlet / outlet fitting kit is to be installed as specified below:

Sch_ma_ECS_simplifi__installation_4_panneaux_portrait.png
Simplified diagram installation of a hydraulic line with 4 panels in portrait



Sch_ma_ECS_simplifi__installation_2_panneaux_paysage.png
Simplified diagram installation of a hydraulic line of 2 panels in landscape

1.  Hydraulic inlet

2. Hydraulic outlet

3. DualQuickfit / Transfer circuit connection

4. DualQuickfit link plug

 

The fluid must flow from bottom to top in the panels.

Respect the hydraulic connection direction (3) at the inlet (1) and at the outlet (2), as shown in the diagrams above and in the table below.

 

Hydraulic inlet (1)

Hydraulic outlet (2)

Portrait

Bottom left

Top right

Landscape

Bottom right

Top left

 

2. Pool system

A kit of compression inlet / outlet fittings for the DN26 inter-panel links allows the inter-panel links to be connected to the transfer circuit.

This kit includes, for a line of panels:

  • 2 x D32/40 mm compression fittings
  • 2 x D32 mm compression caps
kit_de_raccords_entr_e_sortie_PISCINE.png

 

These fittings are installed at the inlet and outlet of each line of panels.

 

The inlet / outlet fitting kit is to be installed as specified below:

Sch_ma_PISCINE_simplifi__installation_2_panneaux_paysage.png

Simplified diagram installation of a hydraulic line with 4 panels in portrait

1.  Hydraulic inlet

2. Hydraulic outlet

3. DualQuickfit / Transfer circuit connection

4. DualQuickfit link plug

 

To authorize the winter draining of the direct pool heating system, the DualSun SPRING panels must imperatively be installed in portrait. The fluid must flow from bottom to top in the panels.

Respect the hydraulic connection direction (3) at the inlet (1) and at the outlet (2), as shown in the diagrams above and in the table below.

 

 

Hydraulic inlet (1)

Hydraulic outlet (2)

Portrait

Bottom left

Top right

 

 

How do DualQuickFit interpanel connectors work?

Was this article helpful?
1 out of 1 found this helpful

Please sign in to leave a comment.